Clover Incinerator

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China.

Waste Incinerator for Cleaner World

Medical Incinerators / Animal Crematory / PLC Incinerators

Contact with Us now for Inquiries

Call us on 0086-25-8461 0201 Email: sales@clover-incinerator.com

Incinerators Spare Parts

Full sapre parts in stock for incinerator operation.

Medical Waste Incineration

Incineration treatment technology for hospital medical waste.

We Work Efficiently

Our Sales Staff and Engineer are Wating for your inquiries and questions.

24/7 Live Support

Get To Know Further Information Before You Purchase. Contact with us by Phone or Email.

How to Delivery?

We arrange incinerator shipping to your local site included shipping cost and insurance.

Get Latest Incinerator Catalogue

Download PDF format Incinerator catalogue for your reference

Incinerator Dispatch Showcase

We delivery different capacity and model waste incinerator to all around the world. Find the business case to know more about the incinerator and us.

Welcome!

Nanjing Clover Medical Technology Co.,Ltd.

www.Incinerator.info  |   Call Us On  +86-25-8461 0201

Company Latest News

Waste Incinerator vs Pet Cremator

Incinerator means same with cremator if you said incineration, but there is some difference. a.) incinerator for waste. VS cremator for animals b.) incineration to be ash and clean it. VS...

Spare Parts for Incinerator

Supply Full Spare Parts Together with Incinerator. Back up Oil Burner or Gas Burner, Temperature Thermocouple, Refactory Cement and Fire Brick in Stock for Continued Maintence. Main parts: Oil Burner,...

Updated workmanship of incinerator chimney

Clover incinerator will updated incinerator chimney (stack) to Stainless Steel material.The new material is able to withstand corrosion and longer lifetime. *according to order

Medical Incinerators Manufacturer in China

*** Primary combustion chamber & secondary combustion chamber *** Smoke filter chamber(dry scrubber) *** stainless steel chimney *** PLC auto. control *** Italy made oil or gas burner(diesel oil/natural gas/lpg)...

ES Fiber Production Line and 400mm Melt blown Production Line and 1600mm Melt blown Production Line and and N95 Mask Machine and Disposable Mask Machine

1. N95 and Disposable Mask Machine   2. 400mm and 1600mm Melt blown Production Line 3. ES Fiber Production Line       N95 Face Mask Machine Production Line Melt...

Clover’s Social Sites

Facebook: www.facebook.com/hiclover Twitter: twitter.com/hiclovercom YouTube: youtube.com/c/IncineratorClover Google+: google.com/+IncineratorClover

Containerized Incinerator

Now you can move your incinerator by truck to anywhere! Containerized waste incinerator is our latest design for market. This incinerator is build in ISO container before leave factory. After...

Medical Waste Incinerator HICLOVER TS10 PLC 10kgs per hour

medical waste incinerator iraq price HICLOVER TS10 PLC 10kgs per hour Items/Model TS10(PLC) Picture   Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion...

1 No. in Primary Chamber and 1No. in Secondary Chamber

No. of burners: 2 Nos. (1 No. in Primary Chamber and 1No. in Secondary Chamber)Type: Monoblock fully automaticFuel: DieselFuel Oil Storage Tank:Shall provide suitable capacity of oil storage tank.Material of Construction: Mild steel.Facility for visual checking of fuel shall be there.It shall have diesel consumption monitoring system.It shall come with diesel oil level indicator, piping with valves & N.R. valve.Control Panel:Type: Manual & Automated PLC based control panel with printer & recording device.Material of Construction: CRCA sheetIt shall have digital temperature controller.Epoxy powder coated washable paint finish.It shall have audio-visual alarm system.Chimney of 30 meters Height:Material of Construction: Mild SteelIt shall be self-supporting type.Height shall be 30 meters from ground level.Paint The chimney is painted externally with two coats of heat resistant aluminum paintShall provide ladder till the top.It shall have 3mm thick rubber lining from inside for protection.It shall come with aviation lamp, lightening arrestor, stack, drain, inspection platform, samplingport.Consumption certificate:The bidder must submit diesel consumption for a daily operation of 6 hours.Turnkey:Prices offered shall be inclusive of all civil works, electrical requirements including cabling andswitches required for installation & commissioning of the equipment.Bidder shall submit detail drawings, design, and layout plan of civil works.The bidder shall submit the details of BOQ of civil and electrical works.Accessories, spares and consumablesAll standard accessories, consumables and parts required to operate the equipment, includingall standard tools and cleaning and lubrication materials, to be included in the offer. Biddersmust specify the quantity of every item included in their offer (including items not specifiedabove).Operating EnvironmentThe system offered shall be designed to store and to operate normally under the conditions ofthe purchaser’s country. The conditions include Power Supply, Climate, Temperature,Humidity, etc.Power supply: 220-240 VAC, 50Hz single phase/400 C 420 VAC, 50Hz three phase asappropriate fitted with appropriate plug. The power cable must be at least 3 meter in length.Standards and Safety RequirementsIt shall have approval of “Pollution Control Board” of purchaser’s country.All mandatory approvals required for the installation and operation of incinerator shall be doneby the bidder.Must submit ISO 9001 ANDCE or USFDA approved product certificate.User TrainingMust provide user training (including how to use and maintain the equipment).WarrantyComprehensive warranty for 2 years after acceptance.Maintenance Service during Warranty PeriodDuring the warranty period supplier must ensure preventive maintenance along withcorrective/breakdown maintenance whenever required.Installation and CommissioningThe bidder must arrange for the equipment to be installed and commissioned by certified orqualified personnel; any prerequisites for installation to be communicated to the purchaser inadvance, in detail.

Laboratory waste Management system

Laboratory  waste Management  system 01. Liqued water purification system. 02. Number of laboratories – 05 03. The estimated liquid water waste – 6000 L including a. chemicals b. toxins c. Bio Hazardous materials. Temporary allocated space for purifications system- 30×20 The following should be indicating in the biding document 1.Method of disposing treated waste water 2.Method of discarding the sludge 3.To follow ISO standard/regulations of Central Environment Authority[CEA] 4.Time frame for construction 5.Request the cost for each item of the project [Consultancy/designing/construction] as well for the whole project. 6.Warranty period and maintaincne.  a. Pre-assembled, containerized type b. Burning rate: 100 – 120kg / hour c. Minimum operating temperature: 8500c (Primary combustion) d. Maximum operating temperature: 14500c (afterburner chamber) e. Secondary Burning capacity: Compulsory. f. Density insulation: 20 mm high g. Refractory casting: minimum 65mm h. Heavy duty refracting lining to withstand 15000c i. Average burn out time: maximum 3.0 hrs j. Fuel type: fuel oil (diesel) k. Fuel consumption in L/hr: 7.5 to 9 l. Residency time in secondary chamber: 2 secs. m. Residue ash post 100kg Max 3.8 kg...

New Year Holiday 2015

Chinese New Year Holiday coming, we will close factory from 14th to 28th Feb. 2015. Thanks for every customer’s supporting during passed year 2014 and we will work hard to...

New Incinerator ready for shipping

Three sets incinerator with 1oo kgs per hour capacity dispatch to Africa customer.

Chinese New Year!

we will be in Chinese New Year Holiday from 25th Jan to 12 Feb, 2014. Thanks for all customer all over the world and our staffs. Best wishes to you...

Hazardous Waste to be Incinerated

Hazardous solid chemical: Different types of combustible solids, used textiles, grease, and toner cartridges, chemicalsfor water purification and photographic consumables and plastic material, emptyplastic/metal cans that still contain remnant hazardous material, oil absorbent. Hazardous liquid chemical:Mainly different types. of Acid, Paint, Varnish, Acetone, White Spirit Aromatic-lessSolvents, Synthetic Liquid for Break Systems, Aircraft De-icing Liquid, Hydraulic andCompressor oil, Freon, used in some older refrigeration units, Insecticide liquid/spray, airrefresh spray and other similar chemicals. Contaminated fuel:Mainly diesel or gasoline contaminated by water or solvents. Used and/or Contaminated oil: Used motor oils and/or mineral oils unfit for their originally intended use. Mainly motorand gearbox oil (approximately 80%) contaminated by a mixture of white spirit and acetone (approximately 51%), hydraulic liquid (approximately 5%). Contaminated water: Waste oilshvater, leaches, hydrocarbons/water mixtures, emulsions and leachate. Contaminated soil: Soil polluted by oil, fuel or 11 chemicals.Contaminated soil polluted by chemicals that has to be recycled in landfill.Contaminated soil—treated and replaced on site. Oil Contaminated SolidsRags, Absorbents, Cardboard, oil and fuel filters, air filters are not consider as hazardous materials. Electronic waste: Waste electrical or electronic appliances or assemblies, including printed circuit boards,containing toxic material and/or heavy metal and/or emitting low radiation. Used battery cells: Dry battery, UPS battery or other types, unsorted waste batteries/ battery cells, containingmaterials that are hazardouy. Used lead-acid batteries:Waste lead-acid batteries, rained/un-drained, and whole or crushed. Hazardous medical waste: Clinical and related waste, arising from medical, nursing or similar practices and wastegenerated in clinics during the investigation or treatment of patients (bio hazard). Expired drugs, solid: Waste pharmaceuticals, drugs and medicines, including sensitive medicines.Expired drugs Iiquid: Waste liquid pharmaceuticals, different type liquid chemicals for treatment, medicalgrease, and paraffin based xpired medicines. Expired and/or contaminated fod: Spoiled fresh food or unusable MRE’s (Meal Ready for Eat – dry food) Onsite Training and Assem Option for Industrial Incinerators I. The bidders should includ 1a price in their offer for training in a central location ( Goma orBukavu) approximately 15 staff in the operation and maintenance of theequipment. Smart Ash Incinerators 1. Size requirement for the incinerators is that the unit works with a 55 gallon open endedsteel drum.2. The unit should operate wit. no fuel and use only 120V or 220V electricity for the blowers.3. The unit should be capable of burning oil contaminated wastes and medical wastes with a moisture content of 0-15%J4. Each unit should come witH two steel drums, so that a spare drum is available. Spare Parts OptionIf there are any vendor suggested spare parts , that list and price should be included as an option in the offer.

New Product Catalogue and User Guide issued

Face mask machine

Zhangjiagang Tengxiang Machinery Co., Ltd. Mobile: 0086-13962221749(whatsapp) Wechat: chncheumg Email: zhangzhonghua@txmc.com.cn  Face Mask Machine for Coronavirus Disease COVID-19 平面口罩机参数: Semi-Automatic Mask Machine l Power supply: 3.3KW mono phase l Mask Size: 175mm*80-100mm (two or...

Company Name Changed

From 17th May, 2013, company name change to be “Nanjing Clover Medical Technology Co.,Ltd.”    The former company “Clover Medical Limited” exists as a subsidiary company.  * Corporation Information Disclosure...

How to instal waste incinerator?

Incinerator Series Model

Clover Incinerator